Generated by All in One SEO v5.0.0.1, this is an llms.txt file, used by LLMs to index the site. # www.jacotesting.com Your source for PCB oil testing ## Sitemaps - [XML Sitemap](https://jacotesting.com/sitemap.xml): Contains all public & indexable URLs for this website. ## Posts - [Jaco Testing News](https://jacotesting.com/hello-world/) - What is ISO/IEC 17025? Why is it important? What is ISO/IEC 17025? ISO/IEC 17025 was first issued in 1999 by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC). It is the single most important standard for calibration and testing laboratories around the world. Laboratories that are accredited to this international standard have - [Jaco is outstanding](https://jacotesting.com/jaco-is-outstanding/) ## Pages - [About](https://jacotesting.com/) - Your source for PCB oil testing - [D-1698 Sediment](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-1698-sediment/) - This test method covers the determination of sediment and soluble sludge in service-aged insulating oils of petroleum origin. Also, provision is made for determining organic and inorganic content of the sediment. The method is intended primarily for oils of comparatively low viscosity. Sediment in insulating oil may deposit on transformer parts and interfere with heat - [D-2668 Oxidation Inhibitor](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-2668-oxidation-inhibitor/) - This test method covers the determination of the weight percent of 2,6-ditertiary-butyl paracresol (DBPC) and 2,6-ditertiary-butyl phenol (DBP) in new or used electrical insulating oil in concentrations up to 0.5% by measuring its absorbance at the specified wavelengths in the infrared spectrum. The quantitative determination of 2.6-ditertiary-butyl paracresl and 2,6-ditertiary-butyl pheonl in a new electrical - [D-3612 Dissolved Gas Analysis](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-3612-dissolved-gas-analysis/) - This test method covers extraction and measurement of gases dissolved in electrical insulating oil and identification and determination of the individual component gases extracted. Oil and oil-immersed electrical insulation materials may decompose under the influence of thermal and electrical stresses, and in doing so, generate gaseous decomposition products of varying composition which dissolve into the - [D-1275 Corrosive Sulfur](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-1275-corrosive-sulfur/) - This test method describes the detection of corrosive sulfur compounds (both inorganic and organic) in electrical insulating oils of petroleum origin. New and in-service mineral insulating oils may contain substances that cause corrosion under certain conditions of use. This test method is designed to detect the presence of, or the propensity to form, free (elemental) - [D-924 Power Factor @100 Degrees C](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-924-power-factor-100-degrees-c/) - This test method describes testing of new electrical insulating liquids as well as liquids in service or subsequent to service in cables, transformers, oil circuit breakers, and other electrical apparatus. Dissipation Factor (or Power Factor) is a measure of the dielectric losses in an electrical insulating liquid when used in an alternating electric field - [D-924 Power Factor @25 Degrees C](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-924-power-factor-25-degrees-c/) - This test method describes testing of new electrical insulating liquids as well as liquids in service or subsequent to service in cables, transformers, oil circuit breakers, and other electrical apparatus. Dissipation Factor (or Power Factor) is a measure of the dielectric losses in an electrical insulating liquid when used in an alternating electric field and - [D-877 Dielectric Breakdown](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-877-dielectric-breakdown/) - This test method determines the electrical breakdown voltage of insulating liquid specimens. The breakdown test uses AC voltage in the power frequency range from 45 to 65 Hz. The dieelectric breakdown voltage is a measure of the ability of an insulating liquid to withstand electrical stress. The power-frequency breakdown voltage of a liquid is reduced - [D-1298 Specific Gravity](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-1298-specific-gravity/) - This test method uses a glass hydrometer to cover the laboratory determination of the density, relative density (specific gravity), or API gravity or crude petroleum, petroleum products, or mixtures of petroleum and non-petroleum products normally handled as liquids, and having a Reid vapor pressure of 101.325 kPa (14.696 psi) or less. Density, relative density (specific - [D-1524 Visual](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-1524-visual/) - This test method for visual examination is applicable to mineral oils of petroleum origin that have been used in transformers, oil circuit breakers, or other electrical apparatus as insulating or cooling media, or both. By use of this test method the color and condition of a test specimen of oil may be estimated. Cloudiness, particles - [D-1500 Color](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-1500-color/) - This test method covers the visual determination of the color of a wide variety of petroleum products, such as lubricating oils, heating oils, diesel fuel oils, and petroleum waxes. Determination of the color of petroleum products is used mainly for manufacturing control purposes and is an important quality characteristic, since color is readily observed by - [D-974 Acid Neutralization](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-974-acid-neutralization/) - This test method covers the determination of acidic or basic constituents in petroleum products and lubricants that are soluble or nearly soluble in mixtures of toluene and isopropyl alcohol. New and used petroleum products can contain basic or acidic constituents that are present as additives or as degradation products formed during service, such as oxidation - [D-971 Interfacial Tension](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-971-interfacial-tension/) - This test method covers the measurement of the interfacial tension between mineral oil and water, under non-equilibrium conditions. Interfacial tension measurements on electrical insulating oils provide a sensitive means of detecting small amounts of soluable polar contaminants and products of oxidation. A high value for new mineral insulating oil indicates the absence of most undesirable - [D-1533 Karl Fischer Moisture](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-1533-karl-fischer-moisture/) - This test method covers the measurement of water present in insulating liquids by coulometric Karl Fischer titration. This test method is commonly used for test specimens below 100% relative saturation of water in oil. Electrical characteristics of an insulating liquid may be affected deleteriously by excessive water content. A high water content may make a - [Dissolved Gas/Oil Quality](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/) - Normal turnaround is 10-15 business days, emergency turn around is also available. Quotations, lab certifications and EPA Performance Evaluations available upon request. Please contact us for pricing or additional information. D-1533 Karl Fischer Moisture D-971 Interfacial Tension D-974 Acid Neutralization D-1500 Color D-1524 Visual D-1298 Specific Gravity D-877 Dielectric Breakdown D-1816 Dielectric Breakdown D-924 Power - [EPA Method 8082](https://jacotesting.com/services/lab-analysis/epa-method-8082/) - Normal Turnaround is 5-7 days on EPA Method tests. Emergency turnaround is available. Oil Soil/Solids Wipes Water Contact us for more information. - [Contact Us](https://jacotesting.com/contact-us/) - P.O. Box 1167 • 103 12th Ave SWEphrata, WA 98823Phone: 800-521-0539 • 509-754-5725Fax: 509-754-4239Email: Customerservice@jacotesting.com Please fill out the form below. - [Lab Analysis](https://jacotesting.com/services/lab-analysis/) - We offer lab analysis for EPA Method 8082 for oil, wipes, and water. Normal Turnaround is 5-7 days on EPA Method tests. Emergency turnaround is available. Normal turn-around for DGA is 10 business days. Rush turnaround is available. We also offer dissolved gas/oil quality tests for D1533 Karl Fischer Moisture, D971 Interfacial Tension, D974 Acid - [Testimonials](https://jacotesting.com/about/testimonials/) - JACO was hired to inspect and sample transformers in our service territory. Over the next 4 years they examined over 5000 transformers, this generated about 200 service orders per year and aided us in removing all units with over 45 ppm PCB’s. Our area is nearly 20,000 square miles, the work would not have been - [Statement of Values](https://jacotesting.com/about/statement-of-values/) - JACO Analytical Laboratory, Inc. has been built on the core values of honestly, integrity, fairness, and loyalty to our customers. Further, we strive to promote: Dedication to customer service and satisfaction. Highest standards of ethics and integrity Continuous improvement: utilize best practices to achieve greatest efficiency and effectiveness. Analysis performed and results reported accurately and - [Mission Statement](https://jacotesting.com/about/mission-statement/) - To respond to industry needs for analytical services using creativity, flexibility, and technical expertise in performing simple or complex analyses with total focus on customer satisfaction and quality workmanship. - [History](https://jacotesting.com/about/history-2/) - JACO Analytical Laboratory, Inc. was formed in April of 1993 in Sioux Falls, South Dakota. In December of 1993, JACO purchased National Chem Lab and moved into its current location at 103 12th Avenue SW, Ephrata, Washington. The laboratory originally performed PCB analysis on oil, soil, and water. In conjunction with JACO Analytical Laboratory, JACO - [TILR Program](https://jacotesting.com/services/tilr-program/) - THE “TILR” PROGRAM TRANSFORMER INVENTORY AND LIABILITY REDUCTION PROGRAM JACO’s Transformer Inventory and Liability Reduction (TILR) program addresses two critical problem areas for electric utilities: (1) PCB Liability/Risk Management, and (2) Electrical Equipment Inventory and Preventative Maintenance. 1. PCB Liability/Risk Management - Both federal and state enforcement agencies have imposed stringent regulations on PCBs, resulting - [Field Oil Testing](https://jacotesting.com/services/field-oil-testing/) - Federal and State legislation have imposed stringent regulations regarding PCB limits resulting in the critical need for utilities to adopt efficient methods to identify PCB contaminated equipment. Implementing a proactive oil testing program is the best solution for a utility to serve the needs of its customers, respond to government regulations, reduce liability risk, and - [Services](https://jacotesting.com/services/) - JACO is a full service company that specializes in obtaining oil samples from energized electrical equipment and sealing the access site with our patented sealant filled rivet. We value efficient, accurate, and complete data collection and providing excellent customer service. - [Certifications](https://jacotesting.com/certifications/) - [Washington PCB Certificate of Accreditation](https://jacotesting.com/certifications/washington-pcb-certificate-of-accreditation/) - [Arizona PCB Certificate of Accreditation](https://jacotesting.com/certifications/arizona-pcb-certificate-of-accreditation/) - [Utah PCB Certificate of Accreditation](https://jacotesting.com/certifications/utah-pcb-certificate-of-acceditation/) - [New York PCB Certificate of Accreditation](https://jacotesting.com/certifications/new-york-pcb-certificate-of-accreditation/) - [ISO](https://jacotesting.com/certifications/iso/) - [Forms](https://jacotesting.com/forms/) - Here are copies of the forms for you to use. DGA/OQ Sample Form Chain of Custody PCB Chain of Custody If you require a digital form, call JACO Analytical at (509) 754-5725. - [Survey](https://jacotesting.com/survey/) - [Video](https://jacotesting.com/video/) - Video 1 - [Gallery](https://jacotesting.com/gallery/) - [Field Testing](https://jacotesting.com/services/field-testing/) - Federal and State legislation have imposed stringent regulations regarding PCB limits resulting in the critical need for utilities to adopt efficient methods to identify PCB contaminated equipment. Implementing a proactive oil testing program is the best solution for a utility to serve the needs of its customers, respond to government regulations, reduce liability risk, and - [Inspection Report](https://jacotesting.com/services/construction/inspection-report/) - [Guard Installation](https://jacotesting.com/services/construction/guard-installation/) - [Equipment Labeling](https://jacotesting.com/services/construction/equipment-labeling/) - [Additional On Site Services](https://jacotesting.com/services/construction/additional-on-site-services/) - [NELAP](https://jacotesting.com/certifications/nelap/) - [Jaco Testing News](https://jacotesting.com/jaco-testing-news/) - [D-5837 Furanic Compounds](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-5837-furanic-compounds/) - This test method describes the determination in electrical insulating liquids of products of the degradation of cellulosic materials such as paper, pressboard, and cotton materials typically found as insulating materials in electrical equipment. These degradation products are substituted furan derivatives, commonly referred to as furanic compounds or furans. Furanic compounds are generated by the degradation - [D-1816 Dielectric Breakdown](https://jacotesting.com/services/lab-analysis/dissolved-gasoil-quality/d-1816-dielectric-breakdown/) - This test method covers the determination of the dielectric breakdown voltage of insulating oils of petroleum origin. The dielectric breakdown voltage of an insulating liquid is of importance as a measure of the liquid's ability to withstand electric stress without failure. The dielectric breakdown voltage serves to indicate the presence of contaminating agents such as - [Oil](https://jacotesting.com/services/lab-analysis/epa-method-8082/oil-4/) - [Soil](https://jacotesting.com/services/lab-analysis/epa-method-8082/oil-3/) - [Wipes](https://jacotesting.com/services/lab-analysis/epa-method-8082/oil-2/) - [Water](https://jacotesting.com/services/lab-analysis/epa-method-8082/oil/) - [TILR Program Components](https://jacotesting.com/services/tilr-program/tilr-program-components/) - JACO’s TILR (Transformer Inventory and Liability Reduction) program addresses the problem areas that your utility faces. The TILR program consists of six main components: 1. PCB Sampling (overhead and underground transformers) 2. Electrical Equipment Inventory and Inspection (overhead and underground transformers) 3. Management Reports 4. Update Utility Maps 5. Computer - [Service Reports](https://jacotesting.com/services/service-reports/) - [Transformer Replacement](https://jacotesting.com/services/transformer-replacement/) - [Animal Protection](https://jacotesting.com/services/animal-protection/) - [Construction](https://jacotesting.com/services/construction/) - [Disposal](https://jacotesting.com/services/disposal/) - [History](https://jacotesting.com/about/history/) ## fSlider - [Accredited with NELAP & ISO/IEC 17025:2017](https://jacotesting.com/fslider/certifications/) - [Oil Sampling From Energized Transformers](https://jacotesting.com/fslider/oil-sampling-from-energized-transformers/) - [About Jaco Testing](https://jacotesting.com/fslider/about-jaco-testing/) ## Portfolio 1 - [Mission](https://jacotesting.com/portfolio_1/mission/) - To respond to industry needs for analytical services using creativity, flexibility, and technical... ## Portfolio 2 - [Tests Performed](https://jacotesting.com/portfolio_2/tests-performed/) - Introductory paragraph about ISO Certifications ## Portfolio 3 - [ISO Certified](https://jacotesting.com/portfolio_3/iso-certified/) ## Categories - [News](https://jacotesting.com/category/news/) - [Testimonials](https://jacotesting.com/category/testimonials/) ## Portfolio 1 Categories - [Mission](https://jacotesting.com/portfolio1_categories/mission/) ## Portfolio 2 Categories - [Tests Performed](https://jacotesting.com/portfolio2_categories/tests-performed/) ## Portfolio 3 Categories - [ISO Certified](https://jacotesting.com/portfolio3_categories/iso-certified/)